Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.584
Filtrar
1.
BMJ Case Rep ; 17(4)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38569739

RESUMO

Osteoid osteoma is a benign osteoblastic tumour with a predilection for the lower extremity that rarely affects the forearm. It is commonly seen in adolescents and young adults, and is seldom diagnosed in the paediatric age group. We report a boy in his early childhood who presented with a swelling over the distal forearm, which was incidentally noted by the mother 3 months ago. Plain radiographs showed diffuse sclerosis of the dorsal cortex of the distal radius. CT scan showed a central lucent nidus in the intramedullary region and surrounding sclerosis in the radial metaphysis, confirming the diagnosis of osteoid osteoma. The patient was successfully treated by surgical en bloc resection of the nidus and was asymptomatic at 1-year follow-up. Non-specific symptoms at presentation make it a challenge to diagnose osteoid osteoma in children and it needs to be considered in the differential diagnosis when radiographs show lytic lesions in the bone.


Assuntos
Neoplasias Ósseas , Osteoma Osteoide , Masculino , Adulto Jovem , Adolescente , Humanos , Pré-Escolar , Criança , Osteoma Osteoide/diagnóstico por imagem , Osteoma Osteoide/cirurgia , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Rádio (Anatomia)/patologia , Esclerose/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Ulna
2.
J Bone Miner Res ; 39(1): 17-29, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38630881

RESUMO

Older men with high bone turnover have faster bone loss. We assessed the link between the baseline levels of bone turnover markers (BTMs) and the prospectively assessed bone microarchitecture decline in men. In 825 men aged 60-87 yr, we measured the serum osteocalcin (OC), bone alkaline phosphatase (BAP), N-terminal propeptide of type I procollagen (PINP), and C-terminal telopeptide of type I collagen (CTX-I), and urinary total deoxypyridinoline (tDPD). Bone microarchitecture and strength (distal radius and distal tibia) were estimated by high-resolution pQCT (XtremeCT, Scanco Medical) at baseline and then after 4 and 8 yr. Thirty-seven men took medications affecting bone metabolism. Statistical models were adjusted for age and BMI. At the distal radius, the decrease in the total bone mineral density (Tt.BMD), cortical BMD (Ct.BMD), cortical thickness (Ct.Thd), and cortical area (Ct.Ar) and failure load was faster in the highest vs the lowest CTX-I quartile (failure load: -0.94 vs -0.31% yr-1, P < .001). Patterns were similar for distal tibia. At the distal tibia, bone decline (Tt.BMD, Ct.Thd, Ct.Ar, Ct.BMD, and failure load) was faster in the highest vs the lowest tDPD quartile. At each skeletal site, the rate of decrease in Tb.BMD differed between the extreme OC quartiles (P < .001). Men in the highest BAP quartile had a faster loss of Tt.BMD, Tb.BMD, reaction force, and failure load vs the lowest quartile. The link between PINP and bone decline was poor. The BTM score is the sum of the nos. of the quartiles for each BTM. Men in the highest quartile of the score had a faster loss of cortical bone and bone strength vs the lowest quartile. Thus, in the older men followed prospectively for 8 yr, the rate of decline in bone microarchitecture and estimated bone strength was 50%-215% greater in men with high bone turnover (highest quartile, CTX-I above the median) compared to the men with low bone turnover (lowest quartile, CTX-I below the median).


Assuntos
Densidade Óssea , Osso e Ossos , Masculino , Humanos , Idoso , Feminino , Estudos Prospectivos , Remodelação Óssea , Rádio (Anatomia)
4.
Nano Lett ; 24(15): 4562-4570, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38591327

RESUMO

Heteroions doped Ag2S nanocrystals (NCs) exhibiting enhanced near-infrared-II emission (NIR-II) hold great promise for glioma diagnosis. Nevertheless, current doped Ag2S NCs paradoxically improved properties via toxic dopants, and the blood-brain barrier (BBB) constitutes another challenge for orthotopic glioma imaging. Thus, it is urgent to develop biofriendly high-bright Ag2S NCs with active BBB-penetration for glioma-targeted imaging. Herein, bismuth (Bi) was screened to obtain Bi-Ag2S NCs with high absolute PLQY (∼13.3%) for its matched ionic-radius (1.03 Å) with Ag+. The Bi-Ag2S NCs exhibited a higher luminance and deeper penetration (5-6 mm) than clinical indocyanine green. Upon conjugation with lactoferrin, the NCs acquired BBB-crossing and glioma-targeting abilities. Time-dependent NIR-II-imaging demonstrated their effective accumulation in glioma with skull/scalp intact after intravenous injection. Moreover, the toxic-metal-free NCs exhibited negligible toxicity and great biocompatibility. The success of leveraging the ion-radii comparison may unlock the full potential of doped-Ag2S NCs in bioimaging and inspire the development of various doped NIR-II NCs.


Assuntos
Glioma , Nanopartículas Metálicas , Humanos , Bismuto , Rádio (Anatomia) , Nanopartículas Metálicas/química , Crânio , Glioma/diagnóstico por imagem
5.
BMC Musculoskelet Disord ; 25(1): 228, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509566

RESUMO

BACKGROUND: Surgical treatment of irreducible distal radius diaphyseal- metaphyseal junction fractures involves difficulties as the fracture remains too proximal for K-wire fixation and too distal for the elastic stable intramedullary nail. Our study aims to present the clinical results of applying an elastic stable intramedullary nail with a poller K-wire to achieve both reduction and stable fixation. PATIENTS AND METHODS: A retrospective analysis was performed on 26 patients who underwent ESIN with a poller K-wire for distal radius diaphyseal-metaphyseal region fracture. Reduction parameters such as residual angulation and alignment were evaluated on postoperative follow-up radiographs. Changes in angular and alignment parameters on follow-up radiographs were recorded. Wrist and forearm functions were evaluated at the last follow-up. RESULT: There were 17 male and nine female patients with an average age of 10.9. The residual angulation in coronal and sagittal planes on immediate postoperative radiographs was 4.0 ± 1.62° and 3.0 ± 1.26°, respectively. The mean translation rate on immediate postoperative radiographs was 6.0 ± 1.98% and 5.0 ± 2.02% in the coronal and sagittal planes, respectively. No change was observed in translation rates in the last follow-ups. The mean angulation in the coronal and sagittal planes measured on 6th-week radiographs was 4.0 ± 1.72°and 3.0 ± 1.16°, respectively. No significant difference was observed in angular changes in the sagittal and coronal planes at the last follow-up (p > 0.05). No tendon injury or neurovascular injury was observed in any of the patients. CONCLUSION: In the surgical treatment of pediatric DRDMJ fractures, applying ESIN with poller K-wire is an effective, safe, and novel method for achieving reduction and stable fixation.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Rádio , Humanos , Criança , Masculino , Feminino , Estudos Retrospectivos , Rádio (Anatomia) , Fixação Intramedular de Fraturas/métodos , Fios Ortopédicos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/etiologia , Resultado do Tratamento , Pinos Ortopédicos
6.
Bioinspir Biomim ; 19(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38452389

RESUMO

Bone is an economical material. Indeed, as moving a heavy skeleton is energetically costly, the vertebrate skeleton is adapted to maximise resistance to the stresses imposed with a minimum amount of material, so that bone tissue is deposited where it is needed. Using bone as a source of inspiration should therefore reduce the manufacturing cost (both financial and ecological) and increase the strength (and lifespan) of bioinspired (BI) structures. This study proposes to investigate which adaptive features of the outer shape and inner structure of bone, related to compressive strength, could be used to build BI support structures. To do so, we explain the choice of the bones to be analysed and present the results of the biomechanical analyses (finite element analysis) carried out on virtual models built from the structures of the different bone models and of the mechanical tests carried out on 3D-printed versions of these models. The compressive strength of these direct bone BI columns was compared with each other, and with those of a conventional filled cylindrical column, and of a cylindrical column whose internal structure is BI from the radius of the white rhinoceros. The results of our comparative analyses highlight that the shape of long bones is less effective than a cylinder in resisting compression but underline the relevance in designing BI cylindrical columns with heterogeneous structures inspired by the radius of the white rhinoceros and the tibia of the Asian elephant, and raise the interest in studying the fossil record using the radius of the giant rhinocerotoidParaceratherium.


Assuntos
Osso e Ossos , Fósseis , Animais , Tíbia , Rádio (Anatomia) , Perissodáctilos , Análise de Elementos Finitos , Fenômenos Biomecânicos
7.
Sci Rep ; 14(1): 7111, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531907

RESUMO

This study aims to measure anatomical data of the capitate bone, develop an external fixator for treating late-stage osteonecrosis of lunate through Ilizarov technique, and evaluate its biomechanical performance. We selected eight wrist joint specimens to measure various parameters of the capitate bone, including its length, the distance from the junction of capitate head and body to the proximal end, as well as the width of its proximal head and distal body. Additionally, we measured these same indicators in 107 patients who had undergone wrist X-ray examination. Based on our measurements, we categorized the capitate bone into two groups and designed two types of capitate bone Ilizarov external fixator (CIEF) for it. Then, we compared it with the orthofix external fixator (OEF) through dynamic fatigue biomechanical experiments and pull-out resistance experiments. The results of the measurement revealed two categories of general patterns in the capitate bone. The first type maintains a consistent longitudinal axis between the proximal and distal ends. The second type is characterized by its proximal end being close to the radial side and its distal end being close to the ulnar side. In the dynamic tensile fatigue test, CIEF-A and CIEF-B had smaller maximum displacement values compared to the OEF (P < 0.05). In the anti-pull-out experiment, both CIEF-A and CIEF-B exhibited higher maximum pull-out force than the OEF (P < 0.05). CIFE is a treatment for advanced osteonecrosis of the lunate bone. It is specifically designed to align with the anatomical characteristics of the capitate bone, providing excellent biomechanical properties and a simple clinical procedure. However, additional clinical experiments are needed to confirm its effectiveness in the future.


Assuntos
Capitato , Osso Semilunar , Osteonecrose , Humanos , Osteonecrose/cirurgia , Articulação do Punho/cirurgia , Rádio (Anatomia)
8.
J Int Med Res ; 52(3): 3000605241233418, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38548472

RESUMO

OBJECTIVES: Despite being an important research topic in oral biomaterials, few studies have demonstrated the differences between poly(d,l-lactide-co-glycolide)/hydroxyapatite (PLGA/HA) and poly(d,l-lactic acid)/hydroxyapatite (PDLLA/HA). In this study, PLGA/HA and PDLLA/HA scaffolds were prepared using three-dimensional (3D) printing technology and implanted into radius defects in rabbits to assess their effects on bone regeneration. METHODS: In this study, 6 mm × 4 mm bone defects were generated in the bilateral radii of rabbits. 3D-printed PLGA/HA and PDLLA/HA scaffolds were implanted into the defects. X-ray imaging, micro-computed tomography, and hematoxylin-eosin staining were performed to observe the degradation of the materials, the presence of new bone, and bone remodeling in the bone defect area. RESULTS: The PLGA/HA scaffolds displayed complete degradation at 20 weeks, whereas PDLLA/HA scaffolds exhibited incomplete degradation. Active osteoblasts were detected in both groups. The formation of new bone, bone marrow cavity reconstruction, and cortical bone remodeling were better in the PLGA/HA group than in the PDLLA/HA group. CONCLUSIONS: PLGA/HA scaffolds performed better than PDLLA/HA scaffolds in repairing bone defects, making the former scaffolds more suitable as bone substitutes at the same high molecular weight.


Assuntos
Ácido Poliglicólico , Rádio (Anatomia) , Animais , Coelhos , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Ácido Láctico , Microtomografia por Raio-X , Durapatita , Impressão Tridimensional , Tecidos Suporte
9.
J Hand Surg Asian Pac Vol ; 29(2): 148-151, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494163

RESUMO

A 15-year-old girl with humeroradial synostosis since birth underwent a resection arthroplasty. A trapezoidal resection osteotomy of approximately 2 cm was performed at the anterior part of the bone flexure. This resulted at 18 months in an elbow arc of motion of 60°-110° and forearm pronation/supination of 40° and 60° without postoperative complications and improved disabilities of the arm, shoulder and hand and Hand 20 scores. Radiographic analysis revealed a humeroradial joint with a maintained pseudarthrosis and hinged motion at the humeroulnar joint. When performed by an experienced surgeon, resection arthroplasty corrects humeroradial synostosis, resulting in improvement in range of motion and quality of life. Level of Evidence: Level V (Therapeutic).


Assuntos
Úmero/anormalidades , Qualidade de Vida , Rádio (Anatomia)/anormalidades , Sinostose , Ulna , Feminino , Humanos , Adolescente , Ulna/cirurgia , Resultado do Tratamento , Osteotomia , Artroplastia
10.
J Hand Surg Asian Pac Vol ; 29(2): 140-147, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494166

RESUMO

Background: The long axis of the radius is a standard reference for measuring radiological parameters in distal radius fractures. However, in patients with severe comminution and anatomical variation with distal radius bowing, it is challenging to assess using the long axis of the radius. The long axis of the ulna can be used as an alternative reference. The aim of this study is to assess the reliability and level of agreement using the long axis of the ulna as an alternative reference in comparison to the long axis of the radius. Methods: Posteroanterior (PA) radiography of the wrist in patients with acute distal radius fractures was evaluated in two rounds by four observers. Radial height, radial inclination and ulnar variance were measured using radial and ulnar long axis as references. The intraobserver and interobserver reliability of the measurements with two reference axes was assessed using intraclass correlation coefficient (ICC). The level of agreement was determined using the Bland-Altman plot. Results: In total, 59 patients who underwent PA radiography of the wrist were included in this study. All parameters exhibited good agreement between the two methods, with a mean difference of nearly zero (radial height = -0.03 mm, radial inclination = -0.14° and ulnar variance = 0.03 mm). The limits of agreement in radial height (-2.87, 2.82 mm) and ulnar variance (-0.81, 0.87 mm) were narrow. However, for the radial inclination, it was wider (-6.21, 5.94°). Intraobserver reliability between the long axis of radius and ulna (ICC = 0.85-0.99 and 0.84-0.98, respectively) was good to excellent. The interobserver reliability of each parameter was excellent (ICC = 0.94-0.97). Conclusions: The ulnar long axis can be used as an alternative reference for measuring radial height, radial inclination and ulnar variance in PA radiography of the wrist in acute distal radius fracture, particularly if the radial long axis is distorted. Level of Evidence: Level III (Diagnostic).


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Fraturas do Rádio/diagnóstico por imagem , Reprodutibilidade dos Testes , Ulna/diagnóstico por imagem , Radiografia
11.
Anal Chem ; 96(13): 5274-5281, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38507515

RESUMO

Investigations about surface energy transfer radius (r0) are limited to the aqueous solution system, and it is quite limited on experimental values of r0 between dyes and the corresponding gold particle (AuNP) sizes, especially for living cell systems. Hence, the selection of suitable AuNP-dye pairs is restricted when designing nanometal surface energy transfer (NSET) strategies in analytical sciences. Here, we developed a single-nucleobase-resolved NSET strategy to in situ measure the r0 value between a specific dye and different-sized AuNPs on the living cell membrane. Using the aptamer-dye complex (XQ-2d-nTA-FAM) and antiCD71 antibody-coupled AuNP conjugate (Au@antiCD71) as two working elements to bind two different sites on CD71 receptors on living cell membranes, we modified the nTA spacer between FAM and the terminal of aptamer to change the distance (r) from FAM to AuNP center and further adjusted the quenching efficiency (Φ) between them. Different r0 values of various AuNP-FAM pairs in living cells are determined by this in situ detection strategy. Based on this single-nucleobase-resolved NSET strategy, we established a simple and efficient universal method for measuring r0 in the living cell system, which greatly expanded the selection range of AuNP-dye pairs during the construction of the NSET model at the nanoscale.


Assuntos
Ouro , Nanopartículas Metálicas , Rádio (Anatomia) , Membrana Celular , Transferência de Energia , Corantes
12.
J Bone Miner Res ; 39(3): 271-286, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38477754

RESUMO

Data on bone microarchitecture in osteogenesis imperfecta (OI) are scarce. The aim of this cross-sectional study was to assess bone microarchitecture and strength in a large cohort of adults with OI using high-resolution peripheral quantitative computed tomography (HR-pQCT) and to evaluate challenges of using HR-pQCT in this cohort. Second-generation HR-pQCT scans were obtained at the distal radius and tibia in 118 men and women with Sillence OI type I, III, or IV using an extremity-length-dependent scan protocol. In total, 102 radius and 105 tibia scans of sufficient quality could be obtained, of which 11 radius scans (11%) and 14 tibia scans (13%) had a deviated axial scan angle as compared with axial angle data of 13 young women. In the scans without a deviated axial angle and compared with normative HR-pQCT data, Z-scores at the radius for trabecular bone mineral density (BMD), number, and separation were -1.6 ± 1.3, -2.5 ± 1.4, and -2.7 (IQR: 2.7), respectively. They were -1.4 ± 1.5 and -1.1 ± 1.2 for stiffness and failure load and between ±1 for trabecular thickness and cortical bone parameters. Z-scores were significantly lower for total and trabecular BMD, stiffness, failure load, and cortical area and thickness at the tibia. Additionally, local microarchitectural inhomogeneities were observed, most pronounced being trabecular void volumes. In the scans with a deviated axial angle, the proportion of Z-scores <-4 or >4 was significantly higher for trabecular BMD and separation (radius) or most total and trabecular bone parameters (tibia). To conclude, especially trabecular bone microarchitecture and bone strength were impaired in adults with OI. HR-pQCT may be used without challenges in most adults with OI, but approximately 12% of the scans may have a deviated axial angle in OI due to bone deformities or scan positioning limitations. Furthermore, standard HR-pQCT parameters may not always be reliable due to microarchitectural inhomogeneities nor fully reflect all inhomogeneities.


OI is a rare condition with large clinical heterogeneity. One of the major characteristics associated with OI is the increased fracture risk due to defects in bone structure and material. Data on the defects in bone structure at the micrometer level (i.e. bone microarchitecture) are scarce. Bone microarchitecture can be assessed noninvasively using HR-pQCT, but its use in OI has not extensively been described. Yet, potential challenges may arise related to among others the occurrence of short extremities and skeletal deformities in OI. We assessed bone microarchitecture and strength in 118 adults with OI types I, III, or IV using HR-pQCT with an extremity-length-dependent scan protocol. Additionally, we evaluated potential challenges of using HR-pQCT in this cohort. Our results demonstrated that predominantly trabecular microarchitecture­especially trabecular number and separation­and overall bone strength were impaired in adults with OI as compared with normative data. Furthermore, we observed various microarchitectural inhomogeneities, most pronounced being trabecular void volumes. Regarding applicability, HR-pQCT could be used without challenges in most adults with OI. However, deviations in scan region may potentially influence HR-pQCT parameters, and standard HR-pQCT analyses may not always give accurate results due to microarchitectural inhomogeneities nor fully reflect all microarchitectural inhomogeneities.


Assuntos
Osteogênese Imperfeita , Adulto , Masculino , Humanos , Feminino , Osteogênese Imperfeita/diagnóstico por imagem , Estudos Transversais , Densidade Óssea , Osso e Ossos/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Rádio (Anatomia)/diagnóstico por imagem , Extremidade Superior , Absorciometria de Fóton
13.
Bone ; 182: 117066, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38438097

RESUMO

BACKGROUND: The use of proton pump inhibitors (PPIs) has been associated with an increased fracture risk in observational studies. However, the reported association between PPI use and bone mineral density (BMD), bone microarchitecture, and bone strength is inconsistent. This study aims to assess the association between PPI use and bone microarchitecture and strength using high-resolution peripheral quantitative CT (HR-pQCT) in a three-year follow-up study in patients with a recent fracture visiting the Fracture Liaison Service (FLS). METHODS: This three-year prospective cohort study included FLS patients aged ≥ 50 years with a recent fracture (median age 62 [IQR 56-69] years, 68.7 % females) and without anti-osteoporosis treatment indication. HR-pQCT scans (distal radius and tibia) were obtained at baseline (T0) and three-year follow-up (T3). Volumetric bone mineral density and bone area, microarchitecture, and strength (micro-finite element analysis) were determined. The association between three-year continuous PPI use and the percentage change in HR-pQCT parameters between T0 and T3 was assessed using sex-stratified multivariate linear regression analyses. Covariates included age, BMI, vitamin-D deficiency (< 50 nmol/l), glucocorticoid use, and cardiovascular co-morbidity (males and females) fracture type (major/hip vs. all others, only males) and probable sarcopenia (only females). RESULTS: In total, 282 participants had available medication data throughout follow-up, of whom 20.6 % were continuous PPI users. In both males and females with complete HR-pQCT follow-up data (males: N = 69 radius, N = 84 tibia; females: N = 147 radius, N = 168 tibia), PPI use was not associated with the percentage change of any of the bone microarchitecture or strength parameters between T0 and T3 at the radius and tibia as compared to non-use. CONCLUSION: Compared to non-use, PPI use was not associated with the change of bone microarchitecture and strength in FLS patients at three years of follow-up. These results do not support that an altered bone microarchitecture or strength may contribute to the increased fracture risk associated with PPI use, as reported in observational studies.


Assuntos
Fraturas Ósseas , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Seguimentos , Estudos Prospectivos , Fraturas Ósseas/diagnóstico por imagem , Densidade Óssea , Osso e Ossos , Tíbia , Rádio (Anatomia)
14.
Bone ; 182: 117072, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38492712

RESUMO

Most postmenopausal women who sustain fragility fracture (Fx) have their areal bone mineral density (BMD) above the osteoporosis threshold. A sizeable proportion of them have normal aBMD. This study aimed to prospectively investigate the association of fragility Fx with bone microarchitecture (MA) assessed by high-resolution peripheral computed tomography (HR-pQCT) in postmenopausal women without low BMD. At the 14th annual follow-up of the OFELY study, we measured bone MA at the distal radius and tibia with HR-pQCT in addition to areal BMD with DXA, in 586 postmenopausal women. Among them, 166 (29 %) women, mean (SD) age 65 (8) yr, had normal BMD defined as a T score ≥ -1 at the lumbar spine, femoral neck, and total hip. During a median [IQR] 15 [14-15] yr of follow-up, 46 of those women sustained incident fragility Fx, including 19 women with a major osteoporotic Fx (clinical spine, forearm, proximal humerus, hip). Women who sustained Fx did not differ for age, BMI, tobacco and alcohol use, diabetes, falls, FRAX®, aBMD, and TBS compared with women without incident Fx. In contrast, they had significant impairment of volumetric densities, cortical area (Ct. Ar) and thickness (Ct. Th), stiffness (K), and estimated failure load (FL) at the radius compared with women without incident Fx. At the radius, each SD decrease of volumetric densities, Ct.Ar, Ct.Th, K, and estimated FL were significantly associated with an increased risk of all fragility fractures with hazard ratios (HR) from 1.44 to 1.56 and of major osteoporotic fractures (HR from 1.66 to 2.57). Lesser impairment of bone MA was seen at the tibia. We conclude that even in women with normal areal BMD fragility fractures are associated with deterioration of bone microarchitecture.


Assuntos
Fraturas Ósseas , Fraturas por Osteoporose , Humanos , Feminino , Idoso , Masculino , Densidade Óssea , Pós-Menopausa , Fraturas Ósseas/diagnóstico por imagem , Fraturas por Osteoporose/diagnóstico por imagem , Rádio (Anatomia) , Tíbia , Vértebras Lombares , Úmero , Absorciometria de Fóton
15.
Osteoporos Int ; 35(5): 919-927, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38507080

RESUMO

Sheehan's syndrome (SS) is a rare but well-characterized cause of hypopituitarism. Data on skeletal health is limited and on microarchitecture is lacking in SS patients. PURPOSE: We aimed to explore skeletal health in SS with bone mineral density (BMD), turnover, and microarchitecture. METHODS: Thirty-five patients with SS on stable replacement therapy for respective hormone deficiencies and 35 age- and BMI-matched controls were recruited. Hormonal profile and bone turnover markers (BTMs) were measured using electrochemiluminescence assay. Areal BMD and trabecular bone score were evaluated using DXA. Bone microarchitecture was assessed using a second-generation high-resolution peripheral quantitative computed tomography. RESULTS: The mean age of the patients was 45.5 ± 9.3 years with a lag of 8.3 ± 7.2 years prior to diagnosis. Patients were on glucocorticoid (94%), levothyroxine (94%), and estrogen-progestin replacement (58%). None had received prior growth hormone (GH) replacement. BTMs (P1NP and CTX) were not significantly different between patients and controls. Osteoporosis (26% vs. 16%, p = 0.01) and osteopenia (52% vs. 39%, p = 0.007) at the lumbar spine and femoral neck (osteoporosis, 23% vs. 10%, p = 0.001; osteopenia, 58% vs. 29%, p = 0.001) were present in greater proportion in SS patients than matched controls. Bone microarchitecture analysis revealed significantly lower cortical volumetric BMD (vBMD) (p = 0.02) at the tibia, with relative preservation of the other parameters. CONCLUSION: Low areal BMD (aBMD) is highly prevalent in SS as compared to age- and BMI-matched controls. However, there were no significant differences in bone microarchitectural measurements, except for tibial cortical vBMD, which was lower in adequately treated SS patients.


Assuntos
Doenças Ósseas Metabólicas , Hipopituitarismo , Osteoporose , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Densidade Óssea , Osteoporose/diagnóstico por imagem , Hipopituitarismo/diagnóstico por imagem , Hipopituitarismo/tratamento farmacológico , Tomografia Computadorizada por Raios X , Tíbia/diagnóstico por imagem , Rádio (Anatomia) , Absorciometria de Fóton/métodos
16.
Cir. mayor ambul ; 29(1): 43-46, Ene-Mar, 2024. ilus
Artigo em Espanhol | IBECS | ID: ibc-231075

RESUMO

La pseudoartrosis es una complicación caracterizada por la ausencia de consolidación del hueso a los 9 meses desde el inicio de la fractura, con falta de progresión radiológica los últimos 3 meses, siendo sus principales causas el exceso de movimiento en el foco de fractura y una insuficiente vascularización. A pesar de no tratarse de una complicación frecuente, los huesos del antebrazo ocupan el 4.º puesto en incidencia de presentación. El manejo anestésico de la patología quirúrgica del miembro superior se realiza generalmente en régimen ambulatorio con técnicas de anestesia regional guiadas por ecografía. Estas técnicas tienen una doble función: anestesia durante el propio acto quirúrgico con una mínima variabilidad sobre el estado basal del paciente y analgesia en el postoperatorio inmediato, permitiendo de esta manera el alta a domicilio de forma más segura y precoz. Presentamos el caso de un varón de 34 años, con desarrollo de pseudoartrosis atrófica tras fractura diafisaria de radio, en el que se realiza injerto óseo de cresta ilíaca y aspirado de células madre como estímulo de la osteogénesis.(AU)


Pseudarthrosis is a complication characterised by the absence of bone healing 9 months after the onset of the fracture, with a lack of radiological progressionin the last 3 months, and its main causes are excessive movement at the fracture site and insufficient vascularisation. Despite not being a frequent complica-tion, the bones of the forearm occupy the fourth place in incidence of presentation. The anaesthetic management of surgical pathology of the upper limb isgenerally performed on an outpatient basis with regional anaesthesia techniques guided by ultrasound. These techniques have a dual function: anaesthesiaduring the surgical act with minimal variability over the patient’s baseline condition and analgesia in the immediate postoperative period, thus allowing forsafer and earlier discharge home. We present the case of a 34-year-old male with diagnosis of atrophic pseudarthrosis following a diaphyseal fracture of theradius, in whom iliac crest bone grafting and stem cell aspiration were performed to stimulate osteogenesis.(AU)


Assuntos
Humanos , Masculino , Adulto , Pseudoartrose , Transplante Ósseo , Transplante de Medula Óssea , Rádio (Anatomia)/cirurgia , Anestesia por Condução , Ílio , Pacientes Internados , Exame Físico , Fraturas Ósseas/cirurgia , Anestesia , Células-Tronco
17.
J Refract Surg ; 40(3): e133-e141, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466766

RESUMO

PURPOSE: To evaluate changes in posterior corneal asphericity (ΔQ) using the tangential radius of curvature after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) procedures. METHODS: One hundred twenty right eyes of myopic patients who underwent either FS-LASIK or SMILE procedures were analyzed using Sirius 3D corneal topography for assessment. The tangential radius was employed to calculate both preoperative and postoperative posterior corneal Q-values across each semimeridian. After both surgical interventions, the ΔQ value variations across the 360° semimeridional regions of the posterior corneal surface were compared. RESULTS: A marked postoperative increase in the posterior corneal Q-value was documented. No significant differences were noted between the postoperative Q-values or ΔQ-values of the two surgical approaches. Among patients with moderate myopia, postoperative Q-value exhibited considerably lower increases and ΔQ-value significantly smaller than their counterparts with high myopia. Moreover, the fluctuation in ΔQ across semimeridional regions was less evident in patients with moderate myopia than in those with high myopia. Notably, the degree of ΔQ fluctuation across semimeridional regions was similar between both surgical categories. These data offer insights into variations in the posterior corneal surface after refractive surgeries depending on the degree of myopia, illuminating their clinical relevance. CONCLUSIONS: Both FS-LASIK and SMILE introduce notable changes to posterior corneal asphericity among patients with different myopia intensities. Furthermore, the influence on the asphericity across the entire posterior surface is similarly distributed between FS-LASIK and SMILE techniques. [J Refract Surg. 2024;40(3):e133-e141.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ferida Cirúrgica , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Substância Própria/cirurgia , Rádio (Anatomia) , Acuidade Visual , Lasers de Excimer/uso terapêutico , Miopia/cirurgia
18.
Vet Surg ; 53(3): 556-563, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38366794

RESUMO

OBJECTIVE: To evaluate the effect of an induced synostosis with a screw on pronation and supination in cats. STUDY DESIGN: Ex vivo biomechanical study. SAMPLE POPULATION: A total of 58 feline forelimbs. METHODS: A total of 58 cadaveric feline thoracic limbs were mounted on a custom-built jig with the elbow and carpus flexed at a 90° angle. To exclude any orthopedic disease, radiographs of the forelimbs were performed prior to the mechanical tests. Radioulnar synostosis was imitated with a 2 mm cortical screw through the radius into the ulna in the proximal (Group P; n = 54), middle (Group M; n = 52), and distal (Group D; n = 53) radial diaphysis. The angles of pronation and supination were recorded after manually applying a two-finger tight rotational force to the metacarpus. Rotational tests were performed without a screw (Group N) and with a screw in each of the aforementioned positions. Pairwise comparisons between the groups were performed based on their angles of rotation with a paired t-test with the Benjamini-Hochberg procedure and a mixed model ANOVA. RESULTS: Mean angles of rotation decreased between Group N (129.5 ± 15.9°) and all groups with imitated radioulnar synostosis to a mean angle of 37.5 ± 14.5° (p < .0001). Mean angles of rotation did not differ between the groups with imitated radioulnar synostosis. CONCLUSION: Induced radioulnar synostosis decreases antebrachial rotation by more than two-thirds, regardless of location. CLINICAL SIGNIFICANCE: Implants fixating the radius to the ulna should be avoided in cats, regardless where they are located along the radial diaphysis.


Assuntos
Doenças do Gato , Rádio (Anatomia)/anormalidades , Sinostose , Ulna/anormalidades , Gatos , Animais , Rádio (Anatomia)/cirurgia , Pronação , Supinação , Ulna/cirurgia , Sinostose/cirurgia , Sinostose/veterinária , Cadáver
19.
Ulus Travma Acil Cerrahi Derg ; 30(2): 135-141, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38305653

RESUMO

BACKGROUND: Although isolated distal radius and radial head fractures are common injuries, simultaneous ipsilateral fractures are uncommon. They can range from simple undisplaced fractures at either end to severely comminuted ipsilateral proximal and distal radial fractures. Few cases have been reported with concomitant comminuted distal radius and radial head fractures, and no treatment guidelines are available. Decisions are often based on personal recommendations. The purpose of our study is to increase awareness of this injury pattern and to discuss the mechanism of injury, treatment approach, and functional outcome. METHODS: Skeletally mature patients with comminuted simultaneous ipsilateral fractures of the distal and proximal radius from 2016 to 2021 were identified and studied retrospectively. Demographic information, mechanism of injury, treatment approach, and complication rate were analyzed. Radiographic assessment for inadequacy or loss of reduction and radiographic parameters of the distal radius, including radial inclination, radial length, and palmar inclination, was performed immediately postoperatively and at the final follow-up. Clinical outcomes were determined by calculating the Visual Analog Scale (VAS) score, measuring the range of motion in both joints, and using the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score at the final follow-up. RESULTS: A total of 11 patients met the inclusion criteria. All had ipsilateral Mason III radial head fractures and type C (according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification) intra-articular distal radius fracture. On-table radial head reconstruction and fixation with a proximal radius plate were used for radial head fractures, and osteosynthesis with an anatomic volar locking plate was used for distal radius fractures. The mean follow-up duration was 32 months (range 12-65 months). At the final follow-up, osseous union of both the radial head and distal radius was observed in all patients. The mean VAS score was 1.5 (range 0-7) at rest and 3.9 (range 0-9) with activities, while the mean QuickDASH score was 32 (range 12-65). No significant complications were recorded. CONCLUSION: Simultaneous comminuted fractures of the ipsilateral distal radius and radial head represent a distinct injury pattern, most likely resulting from high-energy trauma, such as falling from a height onto an outstretched hand. Greater emphasis should be placed on clinical examination and radiological imaging of the elbow in cases of wrist injuries and vice versa. Treatment involving on-table reconstruction of the radial head and open reduction and internal fixation with a volar plate can lead to good radiological and functional outcomes.


Assuntos
Fraturas Cominutivas , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Rádio (Anatomia)/lesões , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Estudos Retrospectivos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Amplitude de Movimento Articular , Placas Ósseas , Resultado do Tratamento
20.
Osteoporos Int ; 35(5): 863-875, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38349471

RESUMO

Non-pharmacological therapies, such as whole-food interventions, are gaining interest as potential approaches to prevent and/or treat low bone mineral density (BMD) in postmenopausal women. Previously, prune consumption preserved two-dimensional BMD at the total hip. Here we demonstrate that prune consumption preserved three-dimensional BMD and estimated strength at the tibia. PURPOSE: Dietary consumption of prunes has favorable impacts on areal bone mineral density (aBMD); however, more research is necessary to understand the influence on volumetric BMD (vBMD), bone geometry, and estimated bone strength. METHODS: This investigation was a single center, parallel arm 12-month randomized controlled trial (RCT; NCT02822378) to evaluate the effects of 50 g and 100 g of prunes vs. a Control group on vBMD, bone geometry, and estimated strength of the radius and tibia via peripheral quantitative computed tomography (pQCT) in postmenopausal women. Women (age 62.1 ± 5.0yrs) were randomized into Control (n = 78), 50 g Prune (n = 79), or 100 g Prune (n = 78) groups. General linear mixed effects (LME) modeling was used to assess changes over time and percent change from baseline was compared between groups. RESULTS: The most notable effects were observed at the 14% diaphyseal tibia in the Pooled (50 g + 100 g) Prune group, in which group × time interactions were observed for cortical vBMD (p = 0.012) and estimated bone strength (SSI; p = 0.024); all of which decreased in the Control vs. no change in the Pooled Prune group from baseline to 12 months/post. CONCLUSION: Prune consumption for 12 months preserved cortical bone structure and estimated bone strength at the weight-bearing tibia in postmenopausal women.


Assuntos
Conservadores da Densidade Óssea , Pós-Menopausa , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Tíbia/diagnóstico por imagem , Densidade Óssea , Osso e Ossos , Conservadores da Densidade Óssea/uso terapêutico , Rádio (Anatomia)/diagnóstico por imagem , Absorciometria de Fóton
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...